After the purchase user receives the intelligent constant temperature and humidity test chamber, unpacking and placing it in the designated laboratory, the test box is fixed by casters. Before positioning, please confirm the size according to the installation space requirements to ensure the maintenance space and door opening space: the initial installation equipment should be placed on the level ground and the cabinet should be horizontally proofread. If the cabinet is not level during the test run, it may cause operational failure. The installation method of the intelligent constant temperature and humidity test chamber casters is as follows:

1. Fixed equipment: After moving the box to the desired position, lower the lifting dial counterclockwise to raise the moving roller to make the fixed base contact with the ground, so that the equipment is basically fixed. At this point, use the level to measure whether the equipment is level. The height of each part of the box can be adjusted by the lifting dial, and each part of the lifting dial is adjusted to the appropriate position and then stopped to ensure that the test box is in a horizontal state.

Second, the mobile device: rotate the lifting carousel clockwise, the fixed base will move up, turn the lifting carousel of each wheel, so that the fixed base of each wheel is off the ground, to ensure that all moving rollers touch the ground, then it is convenient Move the device to the desired location.

The intelligent constant temperature and humidity test chamber is an environmental test machine that provides high temperature, low temperature, high humidity and low humidity. It provides an environment for comparing material changes and strong attenuation before and after testing of rubber, plastics and electronic products. It can also simulate the container environment to detect the fading and shrinkage of rubber and plastic under high temperature and high humidity.

Intelligent constant temperature and humidity test chamber installation place and installation method

1. The placement position should consider the heat dissipation efficiency of the machine and easy to check and maintain.

2. Although the machine itself is made of high-grade stainless steel plate, it is easy to make the machine and electronic controller have adverse effects and cause wrong action or accelerated aging, which should be avoided.

3. The machine should be placed on the plane of the machine with a solid drainage device. The surrounding area should be well ventilated. The bottom of the machine is a refrigeration system. The heat is relatively large. Therefore, it should be installed between the peripheral environment and the wall and any other machine. At least 60 cm or more away from the fuselage for ventilation.

4. Set on the flat and vibration-free ground to install and adjust the four horizontal feet at the bottom of the fuselage to balance the fuselage so that the inner tank can drain and prevent abnormal noise (please check with the spirit level).

5. The installation position of the machine should not be directly exposed to sunlight. Please avoid direct sunlight, so as not to affect the test conditions and maintain indoor air circulation.

6. The installation position of the machine should be as close as possible to other electrical equipment or flammable materials to avoid danger. Please place the machine body in a separate space, not in public places or near flammable, explosive and perishable chemicals. In case of failure, fire and personal injury will occur.

7. Please avoid setting it in a place with a lot of dirt and dust. The ambient temperature and humidity should be maintained at 10 °C ~ 25 °C; between 70 ± 10% RH, the machine can get the best and most stable operation, the consequences may result in: The machine has a slow cooling rate or can not meet the requirements of low temperature, and the temperature control can not be very stable.

8. Do not place any debris on the top of the fuselage to prevent heavy objects from falling and causing damage to the human body.

9. Do not hold the electric box, wires and motor as the driving force fulcrum during transportation to prevent the electrical box electrical equipment from being damaged, loose or causing unexpected failure.

10. The maximum inclination of the furnace body should be below 30° angle. At the same time, the furnace body must be firm to prevent the furnace body from falling down, and the crushing damage or injury to the human body and damage to property.

11. When the machine after positioning needs to be shifted again, please take back the four horizontal feet of the fuselage and shift it, then adjust the balance to avoid damage to the machine.


Benyu manufacturing Caster Wheel,Furniture Casters,Medical Castor,Trolley wheel,industrial caster wheels and Office Casters.

Welcome to contact with us :)

The above is the Talking about the fixing method of the caster of intelligent constant temperature and humidity test box we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> Talking about the fixing method of the caster of intelligent constant temperature and humidity test box
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send